Levels of Workability

The DOE Method defines four levels of workability, which are given in the following table.

Description Slump Range Vebe Time Range
  mm In. Seconds
Very low 0 to 10 0 to >12
Low 10 to 30 to 1 12 to 6
Normal 30 to 60 1 to 2 6 to 3
High 60 to 180 2 to 7 3 to 0